January 18, 1992 - Robin Miller

	This is the modem setup for the DEC DF296 which is necessary
to properly transmit binary files with 'qcp'.  The most important change
is the default flow control under the Speed Buffering (/SBU) section.
The default on my modem was XON/XOFF, which causes these characters to
be eaten by the modem.  I had my best luck disabling the speed buffering
and the DTE flow control.

	Disabling modem echo is also necessary if the DF296 is being used
on a login line, otherwise an infinite loopback condition occurs.

--------------------------------------------------------------------------

              Operational : 

  1   Modem protocol : (1200) Bell 212 =0
                              Reserved =1
                       (2400) V.22bis  =2
                       (1200) V.22     =3
                       (4800) V.32     =4
                       (9600) V.32     =5
                       (9600) V.32TCM  =6
                       (9600) V.32NFB  =7             [6]
  2   Character echo : Off=0, On=1                    [0]
  3   Answer mode    : Auto=0, Man=1                  [0]
  4   Attached msg on incoming call :  Off=0, On=1    [0]
  5   Delete key effect : CRT=0, Hardcopy=1           [0]
  6   Enable Rem Dig Loopback : Off=0, On=1           [0]
  7   Blind Dialing           : Off=0, On=1           [0]
  8   Reserved For Digital Use
  9   Reserved For Digital Use
 10   Reserved For Digital Use

Press RETURN for more ...
 11   Automatic Retrain :     Off=0, On=1             [0]
 12   Speaker enable  : Off=0, On=1 , On if no CD=2   [0]
 13   Speaker volume :    Low=1, Med=2, Hi=3          [1]
 14   Ring to Answer On  Ring = 1 to 10               [1]
 15   Callback Timer     Time = 1 to 6                [1]
 16   Reserved For Digital Use
 17   Reserved For Digital Use
 18   DTE Type   Unknown = 0, VT100 = 1, VTXXX = 2    [2]
 19   Fallback/Fallforward       Off=0, On=1          [0]
 20   Reset on DTR Loss :          Disabled=0
                                   Enabled=1          [0]

Press RETURN for more ...

              Communication : 

  1   Data Bits :  7 bits=3
                   8 bits=4                           [4]
  2   Parity : None=1, Even=2, Odd=3, Mark=4, Space=5 [1]
  3   Stop bits :  One=1, Two=2                       [1]
  4   Off-line XON/XOFF recognition Off=0, On=1       [1]
  5   Communication Protocol : Async=0, Sync=1        [0]
  6   Sync mode timing : Int=0, Ext=1, Slave=2        [0]
  7   DSR forced : On=1, Normal=2                     [2]
  8   EIA CD/CTS Signals   Separate = 0
                             Common = 1               [0]
  9   EIA Speed Select :           Disabled=0
                                   Enabled=1          [0]

Press RETURN for more ...

              Disconnect : 

  1   Send Space Disconnect         Off=0, On=1       [0]
  2   Receive Space Disconnect      Off=0, On=1       [0]
  3   Carrier Loss Disconnect       Off=0, On=1       [1]
  4   Current Loss Disconnect       Off=0, On=1       [1]
  5   Delay to Loss of Carrier     (0-25)
                              (X 0.1secs)
                              (0 = 400ms for BELL212)
                              (0 = 400ms for V.22)
                              (0 = 400ms for V.22bis)
                              (0 = 2secs for V.32)    [0]
  6   Delay to Loss of Current     (0-25)
                              (X 0.1secs)
                              (0 = 10ms)              [0]

Press RETURN for more ...

              Error Correction : 

  1   Error Correction : Off=0, MNP=1                 [0]
  2   Auto Fallback   :  Off=0, On=1                  [1]
  3   Transmit Break Reaction : 
                                Disregard=0
                              Destructive=1
                Non-Destructive Immediate=2
                Non-Destructive Sequenced=3           [3]
  4   Receive Break Reaction : 
                                Disregard=0
                              Destructive=1
                Non-Destructive Immediate=2
                Non-Destructive Sequenced=3           [3]

Press RETURN for more ...
  5   Reserved For Digital Use
  6   MNP Disconnect Type : Non-disruptive=0
                                Disruptive=1          [0]
  7   MNP Compression       :     Disabled=0
                                   Enabled=1          [1]
  8   Accept MNP Link Request : Disabled     =0
                                Anytime      =1
                                Up to 12 secs
                                after connect=2       [2]
  9   Select Maximum MNP Block Size :      64=0
                                          128=1
                                          192=2
                                          256=3       [3]

Press RETURN for more ...

              Speed Buffering : 

  1   Speed Buffering State : Off=0, On=1             [0]
  2   DTE Flow Control : 
                                      None=0
                                X-ON/X-OFF=1
                                   RTS/CTS=2
                                      Both=3          [0]
  3   Autobaud state  :          Off=0, On=1          [1]
  4   Local bit rate :           1200 bps=0
                                 2400 bps=1
                                 4800 bps=2
                                 9600 bps=3
                                19200 bps=4           [3]

Press RETURN for more ...

              Private Line : 

  1   Reserved For Digital Use
  2   Transmit Band : Originate=0, Answer=1           [0]
  3   Interface Type : PSTN=0, PLTN=1                 [0]
  4   Transmit Level : LEVEL = 0-15 (0 dBm to -15dBm) [9]

Press RETURN for more ...

              Access Security : 

  1   Callback Memory Access :   Off=0, On=1          [0]
  2   Dial Memory Access     :   Off=0, On=1          [0]
  3   Parameter Access       :   Off=0, On=1          [0]

Press RETURN for more ...

              Statistical : 

  1   Bit Error Rate :  10E7
  2   Line Level     :  -14
  3   Reserved For Digital Use
Ready